Quantify Scenario B vs A
Across 6 LCA midpoint indicators — full cradle-to-gate inventory.
Sustainable Management of Industrial Processes
For a mid-scale Italian craft brewery — circular valorisation of by-products, process integration, and resource efficiency.
Alessandro
Gazzara
Elisa
Parini
Giacomo Enrico
Spada
Selma
Cerin

Why a 200,000 hL/y brewery in the Po Valley is the right unit of analysis — and what no peer-reviewed study has yet pieced together.
The Scale
≈ 1.2% of national output — capital-intensive upgrades viable.
The Location
The Paradigm + Gap
Physical proximity + complementary streams + stable contracts — the three pre-conditions for symbiosis are already in place in Lodi.
Gap · Research rationale
No peer-reviewed integrated case exists for a mid-scale Italian brewery combining in-house AD, CO₂ recovery and digestate-to-supplier fields.
★ This project is built to fill it.

Problem framing · 03 / 19
Three open loops · one convergent closing strategy
01 / Low-Value By-Products
02 / External Energy Dependency
03 / Open Material Flows
Structural, not managerial — three open loops, one convergent closing strategy.

Aim & Scope · 04 / 19
Across 6 LCA midpoint indicators — full cradle-to-gate inventory.
Base vs PNRR incentive cases — investor-grade view.
Quantify farmer savings, rural employment, and district-level scalability.
Sensitivity on NFRV, grid mix and energy price swings.

Method & Boundaries · 05 / 19
Compliance
ISO 14040 / 14044
Cradle-to-Gate · nutrient loop closed inside
Barley / Hop Fields
CHP · Electricity & Heat
Loop: Digestate → Fields
Brewery Operations · Analytical Core
Functional Unit (FU)
1 hL of beer
at brewery gateBasis for all impact
& cost normalisation
Software
openLCAv 2.7.5
Method
ReCiPe 2016Midpoint · Hierarchist (H)
Databases
BAFU 2025 RER · ELCD 3.2 IT-GridBioenergy + electricity mix references
Energy → Grid / Gas · Digestate → Synthetic N / P / K

Reference Case · 06 / 19
Modelled Factsheet · Linear benchmark
Annual output
Mid-scale craft · Lodi District, Po Valley
Brewery + Utilities + Biogas-to-CHP · physical anchor for Scenarios A & B
Malt
~4,000 tCereal grist intake
Hops
~80 tBittering & aroma additions
Water
~130,000 m³Total intake · 6.5 L / L beer
Thermal
34 TJ / y100% Natural Gas
Electrical
2.78 GWh / y100% Grid mix (IT-ELCD)
BSG
4,000 t→ Animal feed
Wastewater
100,000 m³→ Sewer / public WWTP
CO₂
~700 t→ Vented to atmosphere
Transition from this linear benchmark to the integrated circular model — quantified in Scenario B.

The Integrated System · 07 / 19
The Brewery sits at the centre; biogas from AD and UASB converges on the same CHP; digestate returns to the supplier fields.
Brewery 200,000 hL/y · AD-CSTR + UASB → same CHP · digestate → ~560 ha NVZ-compliant
CSTR mesophilic (38 °C) · internal streams + cattle slurry.
Biogas → net electricity + heat for the brewery. No grid export.
Field injection → closes the nutrient loop on barley & hop suppliers.
Reduces the load on the CHP and valorises process waste heat.
Replaces external food-grade CO₂ purchases · surplus sold.
High-rate anaerobic WW treatment · tail biogas to the same CHP.
Quantitatively focus on the core, while scoping the systemic co-benefits of the support layer.

Mass Balance · 08 / 19
FU = 200k hL / y
FU = 200k hL / y
Malt & Hops
~4,080 t / y
Water Intake
~130,000 m³ / y
Co-substrate · cattle slurry (local partners)
20,000 t / y
24,800 t / y total AD feed
Co-digested with slurry.
23,750 t / y
Returned to supplier fields.
100,000 m³ / y
→ UASB pre-treatment (tail biogas to CHP).
700 t / y · 85% captured
For internal carbonation / sale.

Energy Balance · 09 / 19
~96%
Result · Grid dependency nearly eliminated~27%
Result · Residual ~20 TJ/y on existing NG boilers
CHP heat-to-power ratio ~1.2 vs. brewery thermal-heavy demand ~2.7 — the thermal gap is technology-limited, not design-limited.

Planet · 10 / 19
−3.23kg CO₂eq / hL
Beer produced · vs Scenario A−646t CO₂eq / y
Scenario B vs A
−2.7 kg CO₂eq / hL
−0.7 kg CO₂eq / hL
−0.4 kg CO₂eq / hL
+1.5 kg CO₂eq / hL
Anchor: equivalent to the annual emissions of ~400 Italian passenger cars.

Planet · 11 / 19
The climate benefit is sign-robust across all single-parameter tests — and the one penalty we surface is logistics, not agronomy.
+39 %
Current
+8 %
Mitigated

Profit · 12 / 19 · PNRR Scenario @ 10y
+€1.4M
PNRR @ 10y15.0%
vs Real WACC 7%~5.2y
Discounted−
Fast-payback stress−€0.3 M
NPV @ 10y+€1.5 M
NPV @ 15y−
Honest stress test+€1.4 M
IRR 15.0 % · PB 5.2 y↑
Strong tail value✓
Pass across all horizons✓
Pass across all horizons✓
Pass across all horizons
The Base case is deliberately conservative — that's what makes the PNRR pass robust.

People · 13 / 19
The People pillar is concrete local value — a B2B partnership measured in €, FTE and kg NH₃.
€170k/ y
Full NPK · barley & hop suppliers1.5–1.9FTE
Direct + indirect per installation8–25t / y
Switch from surface-spreading to shallow injection
One installation = a measurable unit of policy leverage for Po Valley PM2.5 control.

TBL Synthesis · 14 / 19
The Triple Bottom Line at a glance — one metric, one result, one status per pillar.
Metric
Climate Change (GWP)
Result
−15.8 %
−646 t CO₂eq / year avoidedStatus
Metric
NPV @ 10y · PNRR 40%
Result
+€1.4 M
IRR 15.0 % · Payback ~5.2 yStatus
Metric
Farmer value & community health
Result
€170k · 1.9 FTE · −15 t NH₃
Per year · per installationStatus
The integration resolves the linear bottleneck, creating a financially viable socio-environmental win under specific boundary conditions.

Synthesis · 15 / 19 · EAC Convention
(−€1.00/hL · −3.23 kg)
Both axes favourable — Win-Win quadrant.
(+€0.21/hL · −3.23 kg)
Environmental win at a small cost premium.
(−€1.64/hL · −3.23 kg)
Co-benefit capture pushes the dot deeper into Win-Win.
NPV → annualised cost / hL — so €-axis & GWP-axis share the same denominator. The ellipse straddles the win-win boundary, combining LCA & economic sensitivity.
Environmentally favourable across the full envelope; economic placement depends on public support. Either way, Scenario B is the structurally superior choice.

Closing · 16 / 19
The boundary conditions of the model — what holds, where, and why.
CHP heat-to-power ratio ~1.2 vs. brewery thermal-heavy demand ~2.7 — fully covering electricity leaves ~73% of heat uncovered.
The paradox: closing the local loop adds +39% Terrestrial Ecotoxicity via 7.5 t lorry brake-wear emissions.
+39% Terrestrial EcotoxicityLesson: true sustainability needs short-radius supply chains (< 5 km) or electrified tractors.
Base case requires a > 10-year horizon to break even — short-term viability (< 6y) is strictly tied to PNRR grants or capturing third-party co-benefits.
Employment impact (1.5–1.9 FTE) uses sector-level benchmarks — not site-specific surveys.

Closing · 17 / 19 · Academic & practical contribution
✓ 4
Gaps Closed○ 1
Frontier OpenFirst rigorous model tailored strictly to the Italian mid-scale band (200k hL/y) — bridging the gap between micro- and mega-scale literature.
Unified internal AD, high-rate UASB and fermentation CO₂ capture into a single, fully balanced thermodynamic circuit.
Directly mapped to the Lodi Po Valley ecosystem, leveraging local co-substrates under strict NVZ regulations (170 kg N/ha/y).
Transitioned from static payback to dynamic 10y / 15y horizons matching current PNRR capital funding frameworks.

Closing · 18 / 19
YES
Under disclosed conditions95 N · 28 P · 73 K
Tonnes / year (N + P + K) returned to supplier soils annually.
~96% el · ~27% th
Electrical & thermal · CHP + PV vs brewery demand.
−15.8% GWP
−646 t CO₂eq / y · sign-robust in OAT.
NPV +€1.4 M
IRR 15.0% · Payback ~5.2y · PNRR @ 10y.
Produce
Affordable & Clean Energy
Retrofit
Industry & Infrastructure
Valorise
Responsible Consumption
Substitute
Climate Action
Return
Life on Land

Closing · 19 / 19
The model holds only where five specific conditions intersect simultaneously — narrow by design.
~1,000 active breweries
100k–500k hL/y · CAPEX-viable mid-scale
≥ 100 cattle/km² · kinetic co-substrate
≥ 1,000 ha cereal land < 15 km · NVZ incentive
Malting barley & hops · N-window compatibility
~10 plants · Lombardia · Veneto · Emilia-Romagna
No micro-breweries, no non-cereal crops.
Primary NFRV measurements + Monte Carlo propagation.
From quantitative proxies to primary stakeholder data.
Upgrading + grid injection vs CHP — head-to-head LCA & econ.
First integrated 4-stream quantification for the Italian mid-scale band.

Closing the Loop
Questions, critiques, and next-step suggestions are welcome — every contribution sharpens the integrated circular model presented today.
Alessandro Gazzara
Elisa Parini
Giacomo Enrico Spada
Selma Cerin